YJ-180 Auto Biochemistry Analyzer
With a stable throughput of 180 T/h (optional 300 T/h), the YJ-180 is tailor-made for small to mid-sized hospitals. Its sealed integrated photoelectric system (no mechanical components) ensures zero maintenance and minimal downtime.

Products Advantages& Distinctive Features
Core Advantages & Distinctive Features
Discrete Random-Access: Fully automated; emergency samples insertable anytime without workflow disruption.
High Throughput: Up to 200 tests/hour for fast result turnaround.
Optional Barcode Scanner: Streamlines identification, reduces manual errors.
Storage Capacity: 30 sample + 60 reagent positions (no frequent reloads).
Intelligent Probe Protection: Auto cleaning, real-time liquid level detection, anti-collision.
Reverse Optics: 8 wavelengths (340–670 nm) for accurate biochemical analysis.
Temperature-Controlled Compartments: Refrigerated storage preserves reagent/sample stability.

Products Operational Features
Random-Access Automation: Fully automated discrete analyzer; prioritizes emergencies.
Cost-Effective Upgrade: Ideal for labs moving from semi-auto to fully-auto.
Advanced Probe: Liquid level detection, 360° anti-collision, inventory monitoring; auto shutdown/alarm on obstacles.
Probe Cleaning: Auto internal/external washing to avoid cross-contamination.
Optical System
Sealed Design: Fully enclosed spectrometry-based system (no mold/corrosion, zero maintenance costs).
Wavelengths: 8 selectable (340–800 nm) for diverse assays.
Absorption Range: 0.00–4.00 Abs (measures high/low concentration analytes).
Long-Lasting Lamp: Tungsten-halogen (>2000 hrs service life).
Precision: Wavelength deviation ≤±2 nm; stray light <0.3%; resolution 0.0001 Abs.
Reagent & Sample Tray
Capacity: 60 reagent + 30 sample positions (supports large batches).
Optional Refrigeration: Reagent tray at 4–12°C (extends reagent shelf life).
Real-Time Monitoring: Auto detects remaining reagent volume; alerts on substrate depletion.
Compatibility: 15/30/50/70ml reagent bottles; supports single/dual reagents (open system).
Sample Dispensing & Rinsing System
Volume Control: Sample (2–100 μl, 0.1 μl increments); reagent (20–500 μl, 1 μl increments).
Water Efficiency: <3L/hour (low utility costs, eco-friendly).
RAQ
Q: 1. What kind of medical equipment does your company specialize in?
Q: 2. Which countries or regions do you export to?
Q: 3. What is your shipping method and delivery time?
Q: 4. What payment methods do you accept?
Q: 5. May we have a tour of your factory?
Q: 6. Do you provide after-sales service?
Q: 7. Can you provide customized solutions for medical devices?
Q: 8. What is your price range for medical equipment?
Q: 9. How can we guarantee the authenticity of your products?
Q: 10. What is your target market for medical devices?
Q: 1. What kind of medical equipment does your company specialize in?
Q: 2. Which countries or regions do you export to?
Q: 3. What is your shipping method and delivery time?
Q: 4. What payment methods do you accept?
Q: 5. May we have a tour of your factory?
Q: 6. Do you provide after-sales service?
Q: 7. Can you provide customized solutions for medical devices?
Q: 8. What is your price range for medical equipment?
Q: 9. How can we guarantee the authenticity of your products?
Q: 10. What is your target market for medical devices?
Contact Information
Tel: +8618237112626
Phone: +8618237112626
Email: forermed@yjcompany.com
Address: Wanda Center, Jinshui District, Zhengzhou, Henan, China
Whatsapp: +8618237112626
Skype: live:.cid.f4a1b4801c7fee8
Wechat: +8618237112626
Hot Tags: Automatic Biochemistry Analyzer With Open System, China, suppliers, manufacturers, factory, low price
Specification of Auto Biochemistry Analyzer YJ-180:
|
Model |
YJ-180 |
|
|
Throughput |
Constant 180T/h (non-ISE) |
|
|
Theory |
Absorption spectrometry, transmission turbidimetry |
|
|
Methodology |
End-point Fixed-timeKineticIon selective electrode |
|
|
Test according set up, random access |
Reaction plate |
Contain 81 reaction cuvettes |
|
Maximum reaction time |
15 minutes |
|
|
Minimum reaction volume |
150 ul |
|
|
Material of cuvettes |
Special UV-transparent optical glass |
|
|
Cuvettes use |
Automatically cuvettes washing |
|
|
Optical Unit |
Light Source |
Halogen-tungsten lamp |
|
Photometer |
Reversed optics |
|
|
Wavelength |
340nm-900nm wavelength option |
|
|
Absorption |
0-4 Abs |
|
|
Reagent Unit |
Reagent plate |
60 reagent positions ,support for single and double reagent, reagent completely open |
|
Reagent storage temperature |
2~10 degree |
|
|
Reagent bottle |
15ml, 20ml, 30ml, 50ml or 70ml ,dead volume is less than 1.0 ml |
|
|
Reagent volume |
20-500 ul, step by 1.0 ul |
|
|
Reagent/Sample Probe |
Automatically checked ;Patent technology liquid level detection;Collision protection probe cleaning:Automatic washing for both inside and outside. |
|
|
Sample Unit |
Sample plate |
60 sample positions |
|
Sample type |
Human (animal) serum plasmaurine etc. |
|
|
Samples cup |
Support one-off micro cups |
|
|
Sample volume |
2-100 ul, step by 0.1 ul |
|
|
Sample/reagent probe |
Automatically checked ;Patent technology liquid level detection;Collision protection probe cleaning:Automatic washing for both inside and outside. |
|
|
Temperature control Unit |
Heating method |
Direct thermal solid thermostat closed |
|
Temperature equilibrium time |
<3 minutes |
|
|
Reaction temperature |
37 ±0.1 degree |
|
|
Temperature fluctuation |
±0.1 degree |
|
|
Operation Unit |
Software |
WindowsXP 2000 |
|
Database |
SQL Server |
|
|
Data Storage |
Automatic store & copy; No time and volume limit; Lifetime preservation |
|
|
Print format |
Can be set up, offer several standard format |
|
|
Calibration mode |
Linear curve type: Single-point linear, two-point linear and multi-point linear none linear; Curve type: Logistic-Log 4P,Logistic-Log5p,Spline,index automatically use best calibration curve and standard |
|
|
Quality control methods : |
Real time, within day & between day |
|
|
Quality control diagram |
L-J cumulative win plot |
|
|
Status display |
Real time monitoring of reagent residual volume .Running status of reagent tray, samples tray |
|
|
Adjustment |
Dynamic and real time display of running status; Intelligent carry over settings to adjust test sequence; original reaction data record; Detail profile of alert messages |
|
|
Setting |
Operation permission setting, Item setting, cross pollution setting, cuvette blank setting |
|
|
Others |
Water consumption : < 6L/h |
Power Supply :AC 220V±22V 50Hz±1Hz |
|
Frequency :Maximum 600VA |
Dimension :782mm×581mm×545mm |
|
|
Net Weight : 60kg |
Accessory :Software |
|