Quantitative Electroencephalogram

Quantitative Electroencephalogram

An electroencephalogram (EEG) machine is a sophisticated medical device that records spontaneous electrical activity in the cerebral cortex.
It collects weak bioelectrical signals from the scalp through electrodes, and after amplification, filtering, and digital processing, generates an electroencephalogram waveform for clinical diagnosis and neuroscience research.
Send Inquiry
Chat Now
Description
Technical Parameters
Products Description

 

 

YJ-EEG16/24/32  Quantitative Electroencephalogram

 

An electroencephalogram (EEG) machine is a sophisticated medical device that records spontaneous electrical activity in the cerebral cortex.

It collects weak bioelectrical signals from the scalp through electrodes, and after amplification, filtering, and digital processing, generates an electroencephalogram waveform for clinical diagnosis and neuroscience research.

Electroencephalography (EEG) machines are based on the bioelectrical phenomena of neurons: when neurons are excited, the transmembrane flow of ions generates a potential difference (action potential), which is transmitted through synapses to form clustered rhythmic electrical activity.

Electrodes capture changes in scalp potential (typically only 2–200 μV), which are then amplified (gain >100 dB) and filtered (to remove power frequency interference, electromyographic noise, etc.) before being converted into digital signals for analysis.

 

Quantitative Electroencephalogram


Application scope:

 

Disease Diagnosis

Epilepsy: Detecting abnormal discharges such as spikes and sharp waves.

Brain Injury and Tumors: Localizing lesions (e.g., increased localized slow waves).

Sleep Disorders: Analyzing EEG changes during sleep.

 

Functional Assessment

Anesthesia Depth Monitoring: Adjusting anesthetic dosage based on EEG fluctuations.

Brain Death Determination: Confirming the absence of electrical activity.

 

Research and Emerging Fields

Brain-Computer Interface (BCI): Decoding thought-controlled external devices.

Neuromarketing: Analyzing EEG responses during consumer decision-making.

 

successful cases

Choose the plan that suits you best.

Quantitative Electroencephalogram

 
1. Method of 10/20 electrodes placement under international standard system, leads can be changed during replaying. Support different types of combined leads during sampling.
 
 

Quantitative Electroencephalogram

 
2. Adopt bioelectricity amplifier for distilling brainwave, continuous recording time can be up to 24 hours, integrated full-automatic calibration system.
 
 

Quantitative Electroencephalogram

 
3. Powerful playback function: amplitude and display speed are adjustable. The special subdividing time line divides the waveform in one second into 5 parts, which is easy for doctors to look over the waveform.
4. Digital filter system can be set as required, providing different window types
 
 

Quantitative Electroencephalogram

5. EEG signal clipping function, analyze and store any section of EEG wave, and select several waveform segments for automatically analyzing and distilling to different parameters.
 
6. Electronic frequency ruler, convenient to measure the basic information of any appointed EEG waveform. With partial enlarging window, accurate measurement of EEG period, amplitude and frequency, which can be adjusted according to personnel judgment.
7. Mark EEG wave under the events of opening eyes, closing eyes and flashing with different colors, and user-defined events can be added, waveform color for evoked event can also be set freely, ensures that the waveform in corresponding time can be rapidly found by event name during case playback.
8. Powerful automatic analysis function, can carry through the power spectrum analysis and pathologic wave detection for appointed waveform. Many graphs can be displayed in the same screen, including kinds of BEAM, numerical BEAM, compressed spectrum graph, trend graph, and so on.
9. Professional isolation transformer, dual power supply isolation system and optoelectronic data transmission to ensure security. Use USB interface to transmit data which just need to be inserted.
10. Multifunctional flash stimulator of USB interface, and flashing can be controlled manually or automatically. A flash stimulation scheme can be set and performed in the process of sampling.
11. Perfect case management function, provides many means for research and quick statistic information; convenient case export and import function, and stores with MO or CD-RW disk, which is easy for data research.
12. Integrative image and character report, report can be edited in mode and switched to Word document.

13. Case files can be transformed into EDF and BDF data format, convenient for data exchange, academic exchange and further analysis.

14. System parameters and display modes can be set as required, which meets different user's requirement. Add marks and annotations to the waveform designated, which can rapidly find the waveform in that time by marks. 

15. Optional video function: USB camera is easy to install, convenient to use and exact to record. With flexible playback function, which can browse the waveform of any time along with the corresponding isochronous sampled image.

 

 

Accessories Standard :

1. EEG lead 2. EEG electrode 3. Data line 4. Headgear 5. Strobe light 

6. Strobe light power supply 7. PC software CD 8. User Manual 

9. Earth wire 10. EEG bracket 11. Aluminum block

 

 

Detailed Pictures

 

 

Quantitative Electroencephalogram

Quantitative Electroencephalogram

RAQ 

Q: 1. What kind of medical equipment does your company specialize in?

A: - Our company specializes in various medical equipment, including but not limited to medical ultrasound scanners, laboratory equipment, ICU equipment and surgical instruments, dental equipment, medical sterilizers, etc.

Q: 2. Which countries or regions do you export to?

A: - Our medical devices are exported worldwide, mainly in North and South America, Europe, Africa and Southeast Asia markets.

Q: 3. What is your shipping method and delivery time?

A: - We offer a variety of transportation options to meet the needs of our customers, including express, air, sea and land. Delivery times vary depending on the destination and the mode of transport chosen.

Q: 4. What payment methods do you accept?

A: - For your convenience, we accept various payment methods, including wire transfer, credit card and PayPal.

Q: 5. May we have a tour of your factory?

A: Of course, we welcome potential customers to visit our factory. Please contact us to arrange a visit.

Q: 6. Do you provide after-sales service?

A: - Yes, we provide comprehensive after-sales service, including product training, repair and technical support.

Q: 7. Can you provide customized solutions for medical devices?

A: - Yes, we have a dedicated team that can provide you with tailor-made solutions to meet your specific requirements.

Q: 8. What is your price range for medical equipment?

A: Our prices are competitive and vary according to the product and quantity ordered. Please contact us for a detailed quote.

Q: 9. How can we guarantee the authenticity of your products?

A: - All our products have CE, ISO, FDA and other certificates.

Q: 10. What is your target market for medical devices?

A: Our target markets include hospitals, clinics and medical institutions around the world, with a particular focus on emerging markets where demand for high-quality medical devices is high.
Contact Information

tel.png

Tel: +8615290808151

phone.png

Phone: +8615290808151

envelope.png

Email: judy@yjcompany.com

address.png

Address: Wanda Center, Jinshui District, Zhengzhou, Henan, China

address.png

Whatsapp: +8615290808151

address.png

Skype: live:.cid.f4a1b4801c7fee8

fax.png

Wechat: +8615290808151

 

 

 

 

 

Hot Tags: quantitative electroencephalogram, China, suppliers, manufacturers, factory, low price

Performance
Sampling rate100 dots/s
Accuracy12bit
Input impedance≥10MΩ
Patient leak current< 10µA
Noise level≤5µVp-p
CMRR≥90dB
Magnification multiple10000
Filter constantall digital and free enactment
Display speed(paper speed)5, 10, 15, 30, 60, 120 mm/s
Amplitude1, 1.5, 2, 3, 5, 7.5, 10, 12, 15, 20, 30, 50 mm/50µV
Playback speed1 time, 2 times, 3 times, 10 times, 20 times, 40 times, 60 times
50Hz interference suppression≥30dB
Safety typeClass II, type BF applied part