YJ-DXP03 Dental X-ray Imaging System
YJ-DXP03 portable dental X-ray machine is an efficient and easy to carry dental imaging equipment.
The device is designed for oral imaging with low output radiation and can take clear pictures even when large doses of radiation are not used.
The inverter frequency of the device is 70kHz, and the high-frequency inverter technology makes the dose more stable, the ineffective radiation is reduced, and the image is clearer.

successful cases
Choose the plan that suits you best.

Radiography

Security

Inverter frequency

Display screen:
Detailed Pictures


RAQ
Q: 1. What kind of medical equipment does your company specialize in?
Q: 2. Which countries or regions do you export to?
Q: 3. What is your shipping method and delivery time?
Q: 4. What payment methods do you accept?
Q: 5. May we have a tour of your factory?
Q: 6. Do you provide after-sales service?
Q: 7. Can you provide customized solutions for medical devices?
Q: 8. What is your price range for medical equipment?
Q: 9. How can we guarantee the authenticity of your products?
Q: 10. What is your target market for medical devices?
Contact Information
Tel: +8618838114181
Phone: +8618838114181
Email: emily@yjcompany.com
Address: Wanda Center, Jinshui District, Zhengzhou, Henan, China
Whatsapp: +8618838114181
Wechat: +8618838114181
Hot Tags: 2d Panoramic X Ray, China, suppliers, manufacturers, factory, low price
|
1 |
Power Adapter |
Input Voltage |
Uniphase AC 100~240V,±10% |
|
Supply Frequency |
50/60Hz,±1Hz |
||
|
Input Power |
286W |
||
|
2 |
Output Power |
25.2W |
|
|
3 |
Charge voltage |
DC 25.2V |
|
|
4 |
Charge current |
1.0A |
|
|
5 |
Nominal value of the focal point |
0.8mm |
|
|
6 |
Anode angle |
19º |
|
|
7 |
Available maximum tube voltage at 2mA |
60kV |
|
|
8 |
Maximum output electric power |
0.12kW |
|
|
9 |
Maximum loading factor combination |
60kV ,2mA ,2s |
|
|
10 |
Repeatability of radiation output |
No more than 0.5 |
|
|
11 |
Tube voltage (The deviation is within the range of ±10%) |
60kV |
|
|
12 |
Tube current (The deviation is within the range of ±20%) |
2mA |
|
|
13 |
Running mode |
Discontinuous operation, maximum excitation (open) time : minimum excitation (close) time = 1:30 |
|
|
14 |
Total filtration of X-ray tube assembly |
>2.5mm Al |
|
|
15 |
Intrinsic filtration of X-ray tube assembly |
0.75mm Al |
|
|
16 |
Additional filtration |
1.00mm Al |
|
|
17 |
Half-value layer |
≥1.5mm Al(60kV) |
|
|
18 |
Leakage radiation |
≤0.25mGy/h(60kV ,2mA ,2s) |
|
|
19 |
Adjustment range of the loading time |
0.01~2.00s,adjustable |
|
|
20 |
Distance of the Focal point to skin (The deviation is within 0~5%) |
211mm±3mm |
|
|
21 |
X-ray field size at the end of beam limiting tube |
round ,Φ 56mm±3mm |
|
|
22 |
Nominal electric power |
0.12kW(60kV ,2mA ,0.1s) |
|
|
23 |
Available maximum tube current at 60kV |
2mA |
|
|
24 |
Inverter frequency of the high voltage generator |
70kHz |
|