HOSPITAL BIPHASIC AED AUTOMATED EXTERNAL DEFIBRILLATOR

Specification | |
Display | |
Screen Type | High-resolution display |
Screen Size | 7 inches(17.7 cm) diagonally |
Sweep Speed | 25mm/sec |
Information | Heart Rate, Lead/Pads, Alarm On/Off, SpO2, AED Functions an d Prompts, Alarm Selection and Limits, Delivered Energy.
|
Defibrillator | |
Waveform | Biphasic |
Charge Time | Less than 7 seconds with a new fully charged battery. |
Energy Display | Monitor display indicates both selected and delivered energy |
Charge Prompt Type | Voice and visual prompts |
Electrode Impedance Measurement Range | 0-2500hms |
ECG Monitoring | |
Patient Connection: | 3-lead ECG cable, or 5-lead ECG cable, paddles.
|
Lead Selection | Displayed on monitor, paddles, I, II, III, AVR, AVL, AVF, V. |
ECG Size | 0.25, 0.5, 1, 1.5, 2, 4 cm/mV diplay on monitor. |
Heart Rate | 20-300BPMHeart Rate Alarm |
Heart Rate Alarm | On/Off displayed on monitor, user-selectable |
Smart Alarms | Beeper/voice prompts indicate shockable rhythm |

Specifications
Display
Screen Type: High-resolution display Screen Size: 7 inches(17.7 cm) diagonally Sweep Speed: 25mm/sec
Information: Heart Rate, Lead/Pads, Alarm On/Off, SpO2, AED Functions an d Prompts, Alarm Selection and Limits, Delivered Energy.
Defibrillator
Waveform: Biphasic
Charge Time: Less than 7 seconds with a new fully charged battery.
Energy Display: Monitor display indicates both selected and delivered energy. Charge Prompt Type: Voice and visual prompts.
Electrode Impedance Measurement Range: 0-250 ohms.
ECG Monitoring:
Patient Connection: 3-lead ECG cable, or 5-lead ECG cable, paddles.
Lead Selection: Displayed on monitor, paddles, I, II, III, AVR, AVL, AVF, V.
ECG Size: 0.25, 0.5, 1, 1.5, 2, 4 cm/mV diplay on monitor. Heart Rate: 20-300BPM.
Heart Rate Alarm: On/Off displayed on monitor, user-selectable. Smart Alarms: Beeper/voice prompts indicate shockable rhythm.
Battery:
Type: Rechargeable, Ni-MH battery, 12V.
Operating Time: For a new, fully charged battery: 60 defibrillator discharges at maximum energy, or 3 hours minimum of continuous
ECG monitoring. Additional parameters will effect operating time with different functions.
SpO2 Module:
Measurement Range: 30~100%, ± 2% between 80%~90%, others ± 5%
Alarm Range: User set high limit and low limit. Alarm Accuracy: ± 10% within setting values. Alarm time Accuracy: Less than 12 sec.
Recorder:
Paper: 50mm thermal.
Speed: 12.5mm/sec, 25mm/sec, 50mm/sec. User-selectable 6-second delay.
Printing Method: High-resolution, thermal print head.
Print-out Modes: Manual or automatic, user-configurable. On/Off Control: Front panel and paddle.
Automatic Function: 9-seconds recording initiated by alarm activation or defibrillator charge or defibrillator discharge.
AED Mode:
AED Function: Auto analyze and charge x3 with programmable
auto energy level selection, screen prompts, and voice prompts. Shockable Rhythms: Ventricular fibrillation with amplitude >=200UV, ventricular tachycardia with rates >=140bpm, and QRS complex wave duration >=140ms.
Charge Control: Control on device front panel, press key on paddle. Prompts: Voice and visual prompts.
Manual Mode:
Energy Selection: Selectable at 2, 5, 7, 10, 20, 30, 50, 70, 100, 150,
200, 300, 360 joules.
Synchronized Mode:
Synchronizes defibrillator pulse to patient's R-wave. "SYNC" message displayed on monitor.
STANDARD ACCESSORIES
ECG Cable (5 Leads) ...... 1Pcs AED Pad connector ........ 1Pcs AED Pad ..........................1pcs
Ground Cable ................ 1Pcs
Power Cable ....................1Pcs
Thermal Paper Role ......... 1Pcs Cleaning Cloth ................ 1Pcs
Packaging Details
Each one is packed individually in a carton Package size : 57x57x26cm
GW: 13.5Kg NW: 11.0Kg
FAQ:
Q:What is time of delivery?
A:Since our products are produced according to each specific order, the delivery period will be 15days after confirmation of order. If it is small or sample order, please do check with us about whether we have ready goods in stock to make delivery as soon as possible.
Q:What about quality assurance?
We offer one year warranty period beginning from the time of shipment for medical equipment, Per minor problems, we can provide free spare parts for replacements, Per serious problems, we can make replacement of free charge. But if the machine is damaged due to rough handling during the transportation, we are free of any responsibility, but we will still provide help to the buyer issue claims against the shipping company or insurance company, thus all the spare parts or expenses should be borne by buyer.
Q:What is payment terms?
A:T/T in advance, Western Union
Q:Which shipping company usually using?
A:MAERSK-LINE, PIL, COSCO, SAFMARINE, MARUBA, APL, CMA, CSAV, K-LINE, MSC, NYK, AND DHL, EMS, TNT, UPS FOR COURIER, buyer's option will be our priority, we will give suggestion according to the schedule and services.
Delivery:

Hot Tags: hospital biphasic aed automated external defibrillator, China, suppliers, manufacturers, factory, low price