Medical Equipment Portable Defibrillator Aed Automated External Defibrillator Unit

Medical Equipment Portable Defibrillator Aed Automated External Defibrillator Unit

YJ-9000D is a compact durable light weighted defibrillator which integrated monitoring manual defibrillation.with 6 parameter patient monitor It is a professional biphasic defibrillator-monitor suitable for hospitals and clinics Standard Configration : Monophasic Defibrillator, ECG.PR.Biphasic function .
Send Inquiry
Chat Now
Description
Technical Parameters

             Medical Equipment portable defibrillator aed automated external defibrillator unit


biphasic defibrillator

Defibrillatorbrillator

(1) brillator type Manual, Synchronized, A synchronized(2) Output waveform:Biphasic technology  (3) Energy accuracy ∠+1

(4)Energyselection 0,3,5,7,10,20,30,50,100,200,300,360joule(no minalataresistance of50) 

(5) Charging time Maximum8seconds to360Joules 

(6) Standard Adult/Pediatric Paddles Reusable external adult paddles (pediatric paddles integrated) 

Power requirements

(a) AC Power supply 110V, 60 Hz /220V, 50 Hz (b) Vehicle Voltage DC 12V 

Internal BatteryBackup (1) Battery type Rechargeable lead-acid battery/ lithium battery (optional) (2) Charging time Time-Minimum of 4 hours for full charging (3) Battery charging During AC Power Supply operation of the device. (4) Battery Capacity 100%ofthe battery will provide 120 minof monitoring; and 30 discharges at 360 joules. 

Display: LED Dimensions 7’diagonal {155mm*88mm} 

Type: Highresolution true-color graphic LED.Resolution:480X234

Screen 7 inches (16.5 cm) diagonal, non-fade.

Type: color (TFT) 

Display Resolution: 800 x 600 pixels. 

Sweep Speed: 12.5mm/s,25mm/s,50mm/s 

Defibrillator type: Manual, Synchronized, A synchronized

Output waveform: Monophonic technology /Biphasic technology (optional) 

Energy accuracy: ∠+1% 

Energy selection: 0,3,5,7,10,20,30,50,100,200,300,360 joule(nominal at a resistance of 50) 

Charging time: Maximum 8 seconds to 360 Joules Standard Reusable external adult paddles (pediatric paddles integrated) Power requirements. AC Power supply :110V, 60 Hz /220V, 50 Hz .DC 12V Battery type: Rechargeable lead-acid battery/ lithium battery (optional) Charging time: Time-Minimum of 4 hours for full charging Battery charging: During AC Power Supply operation of the device. Charging /Low Battery Indication: Red LED Battery Capacity: 120 min of monitoring; and 30 discharges at 360 joules.

ECG 5-leads ECG . 3-leads ECG . 12-leads ECG (option) I, II, III, aVR, aVL, aVF, V- / I, II, III / I, II, III, aVR, aVL, aVF, V1~V6 (option) 

SpO2 Measurement Range:0~100% . Resolution : 1% . Accuracy At 70~100%, ±2% At 0~69%

NIBP Way of measurement: Automatic oscillometry . Range of measurement: Adult . Child . Neo 

HRRange 5-leads or 3-leads ECG module:10~350 bpm . 12-leads ECG module: 25~254bpm 

TEMP Measurement Range: 0.0~50.0℃ , Accuracy: ±0.1℃ . Resolution: 0.1℃ . Unit Celsius: (℃), Fahrenheit (℉) RESP Method: Impedance variation between RA-LL (R-F) . 

Measuring impedance range: 0.2 ~3Ω Excitation frequency: 64.8 kHz ST Segment: Measurement range: -2.0mV~2.0mV

Hot Tags: medical equipment portable defibrillator aed automated external defibrillator unit, China, suppliers, manufacturers, factory, low price