Monopolar Electrosurgical Generator

Monopolar Electrosurgical Generator

Monopolar Electrosurgical Generator Advanced product technology Humanized design Excellent performance and simple operation PURE CUT Low-power setting suits for surgeries need accurate cutting and would not cause ther mal damage, such as plastic,scab cutting surgeries. Higher power setting...
Send Inquiry
Chat Now
Description
Technical Parameters

Monopolar Electrosurgical Generator

high frequency electric knife

Advanced product technology

Humanized design

Excellent performance and simple operation

PURE CUT

Low-power setting suits for surgeries need accurate cutting and would not cause ther mal damage, such as plastic,scab cutting surgeries. Higher power setting (80W~180W) suits for urology surgery,and vaporize electrotomy of obstetrics and gynecology surg eries. BLEND Coagulation effect accompanies with cutting,and applies to surgical operations such a s general,thoracic,abdominal,hysteroscope and urology surgeries. Having adopted the automatic power adjustment technology,the above two modes hav e advantages of high efficiency and low power consumption. Low voltage output specially designed for endoscopic surgeries,greatly reduce risks in herent to such operations. Bipolar macro mode (bipolar cut): specially designed for endoscopic surgery, such as l aparoscopy and hysteroscopy surgery. Adopt the contact quality monitoring system which is proven safe by globe clinical ap plication.

Main technical parameter:

1. Type of the equipment: Model CF, Class I.Anti-defibrillation common equipment.

2.Working frequency: 512 KHz; Working mode : interval loading and continuous operating, temporary loading rate: 10S/30S.

3. Main Output Power:

 

MODEL PURE
CUT
(500Q)
BLEND
1
(500Q)
BLEND
2
(500Q)
BLEND
3
(500Q)
MONOPOL
ARCOAG
(500Q)
BIPOL
ARCO
AG
MACROBI
POLAR
(500Q)
POWER-420D 350W 250W 200W 120W 120W 50W 80W
POWER-420E6 300W 250W 200W 120W 120W 50W 80W
POWER-420A6 350W 250W 200W 120W 120W 50W 1


4. High frequency drain current: 150mA

5. Power supply: single-phase AC220V±22V, 50Hz±1Hz, max.current 3.5A

6. Boundary dimension:456×382×186; packed dimension: 605×530×255

7. Host machine net weight:11.5kg; Machine gross weight: 19.5kg

8.Operation conditions: ambient temperature 5℃~40℃, humidity: 80% RH, Atmospheri cpressure 860 hpa~1060hpa.

9.Transportation and storage conditions:

ambient temperature -40℃~55℃,

humidity <95% RH,

Atmospheric pressure 500hpa~1060hpa.

Hot Tags: monopolar electrosurgical generator, China, suppliers, manufacturers, factory, low price