Products Description
YJ-C8000 Multi-parameter Patient Monitor
Standard parameter configuration: ECG, heart rate, respiratory oxygen, pulse rate, non-invasive blood pressure, body temperature;
Our product has 7 major testing function modules, all independently developed, with its hardware, central processor, and core components.
Its testing accuracy reaches 98%, far ahead of similar monitoring equipment on the market.

Competitive advantage
The company conducted a competitive advantage analysis to identify its strengths and weaknesses compared to its rivals.
Display
* 12.1"real color TFT Screen
Date Storage
Trend diagram/table: 720h
NIBP review:10000 events
Wave review: 12h
Alarm review:200 alarm events
Suppert drug concentration titration analysis
Enviroment
Operating environment:
Temperature: 0~40℃
Humidity:15%~80%
Pressure :86.0 kPa~106.0 kPa
Transport and Storage environment:
Temperature: -20~55℃
Humidity:10%~90%
Pressure:86.0 kPa~106.0 kPa
Power Requirements
AC: 100 ~240V.50Hz/60Hz
DC: Built-in rechargeable battery
Battery: 11.1V 24wh Li-ion Battery
2h operating after full charge
5min operating after low battery alarm
Application Range
Adult/Pediatric/Neonatal/Medicines/ Surgery
Operating Room/ICU/CCU
ST Segment
ST Segment Range: ﹣2.0 mV ~ + 2.0 mV
Accuracy:0.02 mV
Pulse Rate
Measure/alarm range: 20~300bpm
Resolution:1bpm
Accuracy :±3bpm
Optional accessories
IBP CO2 Nellcor SpO2
SpO2
Measurement range: 0~100%
Resolution:1%
Accuracy.:70%- 100% ± 2%
40%~ 69% :±3%
ECG
5 Leads: RA, LA, LL RL, V
Lead mode: I,Ⅱ, Ⅲ,m., AVR, AVL, AVF.V
Gain: x 1.25 mm/mV, 2.5 mm/mV.
5.0 mm/mV, 10 mm/mV, 20mm/mV (error ≤ 5%)
Sweep speed: 6.25mm/s.
12.5mm/s,25mm/s,50mm/s (error ≤ ± 10%)
Bandwidth: Surgery 1~25 Hz
Monitor 0.5~40 Hz
Diagnostic 0.05-130 Hz
Sensitivity: >200 μV P-P
CMRR: ≥ 112dB
Differential Input Impedance: >5M
ohm Electrode Offset Potential:±300mV
Polarization Voltage: ≥± 500mV
Input Impedance: ≥ 5 M
Calibration Voltage: 1 mV ± 5%
NIBP Method
Oscillometry Measure mode:
Manual, Auto. STAT Measure interval in auto mode: 1~5/10/15/30/60/90/120/180/240/480min Measure period in STAT mode: 5min Pulse rate range: 40- 240bpm
TEMP
Channel 2
Measure & alarm range: 0-50 ℃
Resolution: 0.1℃
Accuracy (no sensor) : ±0.1℃ (0-50 ℃ )
RESP
Method: impedance between RA-LL
Resp Impedance range: 0.3-3Ω
Base Impedance range: 200 Ω-4000 Ω
Bandwidth : 0.3 ~2.5Hz
Gain: x 0.25, x0.5, x1,x2 x4
Resp rate:
Measurement Range
-Adult 0 ~ 120BrPM
-Neonatal/Pediatric 0~150BrPM
Resoluition: 1 BrPM
Accuray: 7~ 150BrPM ( ±2BrPM); 0 ~ 6BrPM(unspecified)
Apnea Alarm: 10- 40s
Measure & alam range:
-Adult
SYS 40~280mmHg DIA 10 ~220mmHg MEAN 20 ~240mmHgl -Pediatric SYS 40 ~220mmHg DIA 10- 160mmHg MEAN 20- 170mmHg
-Neonatal
SYS 40~135mmHg DIA 10 ~100mmHg MEAN 20 ~100mmHg
Static pressure measurement Range:0~ 300mmHg
Measure & alam range:
Accuracy:
±3mmHg Resolution: 1mmHg Accuracy Max. Mean Error ± 5mmHg Max. Standard Deviation: 8mmHg Overpressure protection: Adult 300mmHg Pediatric 240mmHg Neonatal 150mmHg
Detailed Pictures

RAQ
Q: 1. What kind of medical equipment does your company specialize in?
Q: 2. Which countries or regions do you export to?
Q: 3. What is your shipping method and delivery time?
Q: 4. What payment methods do you accept?
Q: 5. May we have a tour of your factory?
Q: 6. Do you provide after-sales service?
Q: 7. Can you provide customized solutions for medical devices?
Q: 8. What is your price range for medical equipment?
Q: 9. How can we guarantee the authenticity of your products?
Q: 10. What is your target market for medical devices?
Contact Information
Tel: +8618237112626
Phone: +8618237112626
Email: forermed@yjcompany.com
Address: Wanda Center, Jinshui District, Zhengzhou, Henan, China
Whatsapp: +8618237112626
Skype: live:.cid.f4a1b4801c7fee8
Wechat: +8618237112626
Hot Tags: Multi-parameter Patient Monitor, China, suppliers, manufacturers, factory, low price
|
Standard accessories
|
NIBP cuft & tube
|
|
ECG cable & electrodes
|
|
|
SpO2 sensor
|
|
|
TEMP probe
|
|
|
Lithium-ion battery
|
|
|
Power cable
|
|
|
Operator's manual
|
|
|
Optional accessories
|
IBP
|
|
CO2
|
|
|
Nellcor SpO2
|