Features
• Unique rotary number setter, easy and quick parameter setting
• Dual-MPU design, more secure system operation
• Comprehensive audible and visual alarm function, adjustable volume and 360 visible
• Swift priming and flushing function available
• Memory and recall function for last setting
• Ultrasonic bubble detection technology
• Instant detection of dynamic pressure, facilitating clinical monitoring & prediction, and lowering occlusion risks
• Emergency power supply with removable battery for swift transportation and maintenance
• Reserved port for optional exclusive thermostat
• Embedded handle for better space-efficiency
• USB port for system upgrade and data storage
• Optional exclusive/universal feeding sets, higher feeding accuracy and lower occlusion risks
|
Technical Specifications |
|
|
Infusion rate (ml/h) |
1~400 ml/hr in 1 ml increments |
|
Mean flow velocity accuracy |
±10% of selected flow rate |
|
Dosage limit(ml) |
0-9999 in 1 ml increment |
|
Meanvolume accuracy |
±10% |
|
Loading speed andmeanaccuracy (ml/h) |
1000±10% |
|
Cleaning speed andmeanspeedaccuracy(ml/h) |
1000±10% |
|
Max volume flushandmeanspeed accuracy(ml) |
40±10% |
|
Mx feeding pump pressure |
≥0.1 MPa |
|
Occlusion alarm level (pressure) |
50KPa±10KPa |
|
The longest occlusion triggering time of this device at minimum flow rate |
43min |
|
The shortest occlusion triggering time of this device at intermediate flow rate |
85s |
|
Medium speed running the pills from blocking the alarm threshold |
0.79ml |
|
Recoverable Alarm |
1min50s-2min |
|
Pause overtime alarm time |
1min50s-2min |
|
Heating temperature |
Infusion flow rate ≥20ml / h, 375px distance away from the heater outlet at 25-38 ºC |
|
Use ofinfusionset |
See recommended infusion sets list |
|
Air-in-line sensitivity |
Detestability of single size of air bubble ≥50uL |
|
Alarm |
Occlusion alarm, Over heatedalarm, battery depleted alarm |
|
Alarms |
Air in line,Prime, Flush, low power, failurecodes (ERxx), pause overtime, powerstate, infusion mode, work state, heaterstate. |
|
Noise |
Measured at the highest flow rate on wooden table, the volume is lower than 50 dB at a distance of 1 meter |
|
Power |
Ac: 100V-240V 50 Hz /60Hz |
|
Built inbattery |
A fully charged internal DC11.1V battery can continuously run the pump for approximately 5 hours on intermediate rate |
|
Power consumption |
≤40VA |
|
Power output |
≤20VA |
|
The rated output voltage |
15V |
|
Weight |
2.0kg |
|
Heater |
W-E01 ,cable length is 1.5m,Shield |
|
Essential performance |
This product is suitable for patients with enteral nutrition infusion, the host cancontrol the infusion rate. With alarmfunction, |
|
Classification |
type BF,class ΙΙ continuous volumetric feeding pump with internal battery; IPX1 (sealed drip-proof device) |
|
Dimensions |
155mm(L)×170mm(W)×180mm(H) |
|
Accessories |
1 user manual, 1 power cable, 1 heater (EA312/313 models only) |