Features
•3.5-inch LCD screen,Multiple languages Customization
•Wide range of flow rate:0.01-1800ml/h
•Automatic recognition of syringe specifications(5ml, 10ml, 20ml, 30ml, 50/60ml)
•Dual-CPU design, more secure for system operation
•Comprehensive audible and visual alarm function, adjustable volume, visible from 360
•Dynamic pressure detection technology
•Drug library mode, customized version(optional), weight mode
•Change flow rate without stopping the current task
•Emergency power supply
•Nursing call port through RS232/WiFi
•Stackable and upgradable for workstations, better space efficiency with integrated power supply
Powerful alarm system with 360 visual light signs, easy for identification.
Manual & automatic bolus, can be programmed according to clinical use;
Automatic anti-bolus to decrease unexpected clinical risk.
Top accuracy in the world: +-2%, flow rate increments by 0.04ml/h.
Easy calibration of syringe and volume etc, For more friendly use.
Drug library contains more than 50 drug names, and can be updated & programmed.
Three infusion modes including Rate, Time, Body-weight.
DPS (Dynamic pressure system)
Hot Tags: yj-fc113 syringe pump, China, suppliers, manufacturers, factory, low price
Technical specification:
|
Model |
YJ-FC113 |
|
Applicable syringes |
5ml,10ml,20ml,30ml,50ml/60ml |
|
Infusion Modes |
Rate Mode, Time Mode, Body-Weight Mode |
|
Drug Name Display |
More than 50, Can be updated according to customer requirements or clinical use |
|
Accuracy |
+-2% |
|
Time Preset |
0-99h and 59min |
|
Flow Rate step by |
Increments at 0.01ml/h |
|
Flow rate |
5ml: 0.01-150ml/h 10ml: 0.01-400ml/h 20ml: 0.01-600ml/h 30ml: 0.01-900ml/h 50ml: 0.01-1800ml/h 60ml: 0.01-1800ml/h |
|
Safetly |
Double CPU to make sure higher standard infusion |
|
Volume limit |
0.1-9999.99ml |
|
Purge/Bolus Rate/Top flow rate |
5ml: 150ml/h 10ml: 400ml/h 20ml: 600ml/h 30ml: 900ml/h 50ml: 1800ml/h 60ml: 1800ml/h |
|
Audible&visible alarms |
syringe dislocation, occlusion , near end, pause overtime, low battery, battery exausted, VTBI completion, syringe empty, motor malfunction, incorrect syringe specification, Circult Malfunction, internal communication malfunction, master CPU malfunction, monitoring CPU malfunction. |
|
KVO |
Rate≥10ml/h: KVO=3ml/h, Rate<10ml/h: KVO=1ml/h |
|
Occusion pressure |
High: 106.7kpa+-26.7kpa, Middle: 66.7Kpa+-13.3Kpa Low: 40.7kpa+-13.3kpa |
|
Pause overtime alarm |
1min 50s-2min |
|
Power & Battery |
20VA AC:100V-240V 50HZ/60HZ DC:11.1V Ni-MH battery support from 7 to 10hours |
|
Calssification |
Class II, type CF, IPX4 |
|
Operation Condition |
Temperature: +-5C--+40degree C, Relative Humidity: 20%-90% Atmospheric pressure 70Kpa-106Kpa |
|
Optional Function |
Event log with at least 2000 history records;DC |
|
Dimensions |
140x260x110mm |
|
Weight |
2.5kg |