1. Purchasing an instrument or purchasing a detection system
1.1 Detection system According to the past concept, the purchase of equipment is to purchase instruments according to the cost performance. However, with the improvement of inspection management, the government has put forward higher requirements for each inspection item carried out by the inspection department. The Ministry of Health issued a notice on the "Administrative Measures for Clinical Laboratories in Medical Institutions" (Weiyifa [2006] No. 73 ) (hereinafter referred to as the "Administrative Measures") pointed out: "The clinical laboratory of a medical institution shall ensure the integrity and effectiveness of the detection system".
1.2 The importance of purchasing a testing system The quality of the testing system will directly affect the precision, accuracy and traceability of the testing results, but it is difficult for clinical laboratories to evaluate the testing system for each testing item. Therefore, in addition to providing instruments, manufacturers also provide supporting reagents and supporting calibrators, and also stipulate operating procedures, forming a reliable and traceable detection system. In the 1990s, the US FDA and the relevant departments of the European Union have clearly stipulated that when applying for a product license, it is no longer the approval of one instrument, but the declaration and approval of the entire testing system. The user tests patient specimens according to the specified detection system (ie, closed system), and the quality is guaranteed
2. Formal training of operators
2.1 The content of formal training The instrument must be operated by people, and the level of the operator will determine whether the detection system can obtain correct results, so formal training is very important. The current situation is: after purchasing the instrument, the engineer comes to install it very quickly. Generally, there is no calibration, and no detailed installation report is written. The operator is only taught a simple operation, and the report can be printed out. The fastest is only half a day. Obviously, such training cannot meet the requirements. Since the operators have not received formal training, they are often only able to operate but not calibrate, and the daily maintenance of the instrument cannot be guaranteed. Generally, the manufacturer's engineer is only called when a fault occurs.
2.2 Organization and implementation of training work Because blood cell analyzers are widely used, there are many manufacturers, and the models of instruments in each factory are different, and the principles are not necessarily the same. The author believes that the more realistic method is: instrument manufacturers should Pre-job training is one of our after-sales technical service tasks. Those who have passed the training should master the skills of regular calibration, analyzing quality control results, interpreting reports, daily maintenance, and troubleshooting, and write all records during the use of the instrument, which is also in line with the "Management Measures" for quality assurance and reducing instrument failures requirements. After the formal training for customers, the repair rate of the instrument will be significantly reduced, achieving a win-win situation for both the supplier and the user.
3.Re-examination after blood analyzer test
3.1 Re-examination standards are formulated for re-examination after automatic blood analyzer counting and leukocyte differential counting. The international hematology expert group recommended 41 automatic CBC and DC re-examination standards. The re-inspection standard is interpreted. The establishment of automatic blood cell count and white blood cell count re-examination rules has important guiding significance for clinical laboratories at all levels in my country. Long-term clinical practice has proved that the results of blood analyzers are only for screening. In the absence of specific re-examination standards in our country, each laboratory should formulate a standard according to the type and model of the instrument and the knowledge level of the staff. The actual re-inspection standards are implemented in the post, listed in the operation manual, and strictly implemented. In addition to microscopic re-examination, verification of some manual methods should also be included. At present, there are still many units that have not carried out re-inspection.
3.2 Strengthen the training of inspectors under the microscope With the popularization of blood analyzers, the idea of blindly relying on the instrument has become more and more serious, which greatly weakens the training under the microscope, and even the red and white blood cells in the body fluids are also unclear. The morphological description of red and white blood cells was not seen in the report, and even the neutrophil toxic lesions disappeared from the report. The phenomenon of missed detection, missed diagnosis and misdiagnosis occurred frequently. It should be clearly recognized that the examination under the microscope is still a basic method of morphological examination and plays an irreplaceable role in the diagnosis and treatment of some diseases. The morphological examination of blood cells is still the main content of CBC, and it is also a basic skill that inspectors must master. They should be familiar with and mastered through years of training and accumulation.