Small Size Infusion Pump

COMPACTAND PORTABLEEASYTO LEARNAND USE
Patented quick-hook system,easy to plug and install.
LCD screen,high-contrast,simple to read
Compact body design saves bedside space
FRIENDLY DESIGNEFFICIENTASSISTANCE
Intelligent block-removal system,automatically release the pipeline pressure after blockage
High capacity lithium battery,facilitates patient transfer
Infusion logs can be downloaded via Wi-Fi
STABLE PERFORMANCEANDMULTIPLE ALARMS
Multiple alarm functions strict management of infusion process
Dual CPU architecture to ensure safety and reliability
Ultrasonic bubble detection technology unique
algorithm eliminates false alarm
Main performance:
Adjustable AIL sensitivity
Upstream occlusion alarm
2.8 inch touch
Color TFT Touch Display
Operate with gloves
Redundant keys for usability and safety
Technical Specification: | |
Range of flow rate setting Flow rate accuracy (Essential Performance) | 0011800m/ 15% Note: One pump and ten IV sets far the accuracy test. |
VTBI (Volume to be Infused) range | 0.01-9999.99ml step by 0.01ml |
Infusion volume accuracy (Essential Performance) | 15% Note: One pump and ten IV sets for the accuracy test. |
Purge rate | 1ml/h-1800ml/h adjustable:±20%; |
Occlusion alarm(pressure (Essential Performance) | 100kP8120kP8_50kP8420kPa High: 100kPa±50kPa Low:50kPa±20kPa |
Maximum infusion pressure | 16CkPa |
Time to activate the occlusion alarm, max bolus (Essential Performance) |
Minimum flow rate: occlusion alarm is activated when pressure is within 50kPa+20kPa tor 20 minutes. And when pressure is within 120kPa+20kPa for 45 minutes. Intermediate flow rate: occlusion alarm is activated when pressure is within 40kPa±20kPa for 1 minutes and 30 seconds, or when pressure is within 100kPa±30kPa for 2 minutes and 30 seconds,and the bolus produced is less or equal than 0.7ml The minimum selectable rate is the minimum flow rate. It equals to 1 mL/h The time to activate the occlusion alarm is the same as minimum flow rate The minimum selectable rate is the minimum flow rate. It equals to 1 mL/h The time to activate the occlusion alarm is the same as minimum flow rate. (Jerry infusion set is used to create occlusion at the end of infusion line during verification test. Measure environment is 20°℃, and patient line is 1 meter) |
KVO Rate | Flow rate ≥ 10muh KVO rate=3mi'h; 1mlh ≤Flow rale <10ml/h. KVO rate = 1mih Flow rate < 1mi/h, KVO rate = flow rate |
Recover time after the recoverable alarm sound is cleared. | 1min50s~2min |
Time for pause over time alarm. | 1min50s~2min |
High priority alarm (Essential Performance) | Door open alarm, occlusion alarm, VTBI completion alarm, air in line alarm, out of battery alarm, battery/mains power double disconnect alarm, malfunction alarm. |
Classification | Class II Type CF, capacity infusion pump with internal power source for continuous operation, IPX2 |
Environmental Requirement | Storage Temperature-30℃~+55℃; |
Operation Temperature:5℃~+40℃; | |
Storage relative humidity:$75%; | |
Operating relative humidity:20%~90%; | |
Barometric pressure range: 80.0kPa~106.0kPa. | |
Software Version | V1.0.0 |
Lifetime | 5 years |
Infusion Pump Detailed Description:
For all patients
Adjustable AIL sensitivity Upstream occlusion alarm
More
Over ten safety alarms
Adjustable occlusion and AIL sensitivity Support drop counter. Battery Life>=7hrs
Achieve 5% accuracy at2200ml/h IPX 4
External Power Supply
External power supply to reduce the risk of
power overheating.Optional one for two power
supply to save power outlet for stackable configuration
Three steps to start
Intuitive operation. 1.Set up the parameter with dials2.confirm with the push botton and 3.start therapy with start button.
i+
Download setting and upload therapy data via WIFI.
Support infusion therapy analysis and statistics.
Help the healthcare giver to improve therapy