YJ-EA323 DOUBLE FEEDING PUMP

Features:
• LCD color screen,Multiple languages
• Hydrating while feeding
• Auto-flush & pre-flush for anti- Occlusion function
• Unique rotary number setter
• Dual-MCU design
• Comprehensive alarm function
• Ultrasonic bubble detection technology
• Sensitive detection of dynamic pressure
• 72 hours feeding history available
• A variety of feeding modes:Continuous mode,Intermittent mode,newborn mode
• Emergency power supply
• Exclusive thermostat (optional)
• Exclusive feeding sets:spike+flushing bag/feeding bag+flushing bag
• 360 adjustable quick-mount pole clamp
Hot Tags: yj-ea323 double feeding pump, China, suppliers, manufacturers, factory, low price
Technical Specifications:
|
Infusion preset range (ml) |
Feeding volume: 0-9999, adjusted by 1 |
|
Infusion(feeding or watering) accuracy |
±10% or±0.2ml/h(choose the larger value) |
|
Feeding speed setting range (ml/h) |
1~800, adjusted by 1 |
|
Feeding speed accuracy |
±10% or±0.2ml/h(choose the larger value) |
|
Water feeding speed and accuracy (ml/h) |
1000±10% |
|
Flushing speed and accuracy (ml/h) |
1000±10% |
|
Single Flushing dose (ml) |
25±10% |
|
Perfusion speed and precision (ml/h) |
1000±10% |
|
Perfusion dose (ml) |
10ml±10% nutrition and 25ml±10% water |
|
The Maximum infusion pressure |
≤0.1 MPa |
|
The trigger alarm time at minimum flow rate |
42min18s |
|
The trigger alarm time at medium flow rate |
1min30s |
|
The amount of bolus produced by Medium speed up to the blocking alarm threshold |
0.49ml |
|
Blocking alarm threshold (pressure) |
50KPa±10KPa |
|
The recoverable time when alarm is automatically restored after the time is out |
1min50s - 2min |
|
Pause time when alarm timeout |
1min50s - 2min |
|
The heating temperature |
When the feeding speed is greater than 20ml/h,15cm distance heater outlet is 25-38ºC |
|
Bubble sensitivity |
A bubble that can detect a single volume greater than 50uL |
|
Intestinal feeder |
Special intestinal feeding device |
|
Alarm function |
Tube occlusion, battery exhaustion, overtemperature |
|
Prompt function |
Tubing Bubble, Infusion Completion, Flush Completed, Battery Under voltage, Equipment Failure (ER Series), Pause Timeout, Network |
|
Noise |
Internal rechargeable lithium battery 11.1V; |
|
Power supply and input |
100-240V ~ 50 /60Hz ≤40VA |
|
Internal battery |
Internal rechargeable lithium battery 11.1V; |
|
Output |
≤20VA |
|
Rated output voltage |
DC15V |
|
Total Weight |
About 1.5kg |
|
Rate |
Class II BF type continuous operation capacity type nutrition pump with internal power supply; |
|
Dimensions |
135mm (L) ×105mm (W) ×160m (mH) |
|
Accessory |
1 User's Manual and other document, 1 adapter, 1 set of intestinal feeding device and heater |