1. Power socket: need to be grounded safely.
2. The operator must closely observe the patient's response during the treatment, and the treatment can be terminated if the patient feels pain.
3. The operator must observe the operation of the instrument at any time. If the instrument is abnormal, immediately terminate the treatment, turn off the power switch on the instrument, and check for malfunctions.
4. Fallopian tube fluids should be performed within 3-7 days after menstruation is clean, and fallopian tube fluids are usually done every other day; uterine cavity testing and treatment should be performed at the time except for the high-risk period of menstruation. The detection and treatment of the uterine cavity and the oviduct drainage cannot be performed continuously on the same day.
5. Before entering the examination and treatment, the patient should be checked to confirm that the patient is indeed not pregnant.
6. Check the patient's leucorrhea routine, blood, urine routine, body temperature and blood pressure before using this instrument.
7. During the treatment process, the medical staff shall not leave the treatment site, pay attention to observe the condition of the patient and the treatment instrument, and immediately stop the machine if any abnormality is found.
8. When using the instrument to check or treat the patient, the emergency brake handle must be placed in the patient's hand, and the patient should be told to press the button on the front end of the emergency brake handle when they feel unwell.
9. One-time use of the three-way catheter to the sensor outside the casing of the interface, after injection and treatment, there should be about 15 cm of isolation air in the tube, the entire pipeline should be sealed, otherwise the liquid will flow into the sensor interface, causing The instrument is damaged.
10. When replacing the fuse of the instrument, first turn off the power switch of the instrument and then unplug the power plug to replace the fuse of the same model;
11. Do not spill liquid on the instrument panel and sensor;
12. The instrument shall not be exposed to ultraviolet rays for a long time.
13. The included syringe, Y-shaped three-way tube, double-chamber fluid tube, and uterine dilation tube are disposable equipment prepared for the test machine, and should not be used in clinical practice.
14. Each bottle of liquid medicine can only be used by one person.
15. Disposable consumables for inspection and treatment (such as syringes, Y-shaped three-way tubes, double-chamber fluid tubes, uterine dilation tubes, etc.) must not be reused.
16. When the instrument is working, if there are energy radiating equipment such as microwave, radio frequency, X-ray, etc., it may cause interference to the instrument. Keep the instrument away from these equipment as much as possible.
17. Disposable consumables discarded after inspection and treatment should be disposed of in accordance with the relevant regulations on medical waste.