Electrocardiography (Electrocardiography, ECG, or EKG) is a diagnosis and treatment technique that records the electrophysiological activity of the heart in units of time through the body wall and captures and records it through electrodes that touch the skin. This is a non-invasive recording method.
The etymology of Electrocardiography comes from three Greek words: "electro", because it is related to electrophysiological activities, "cardio", the Greek "heart", and "graph", a Greek root meaning: "description".
The working principle of the electrocardiogram: every time the heartbeat depolarization of the myocardial cells will cause a small electrical change on the skin surface, this small change is captured by the electrocardiogram recording device and magnified to describe the electrocardiogram. When the cardiomyocytes are in a resting state, there is a potential difference formed by the difference in the concentration of positive and negative ions on both sides of the myocardial cell membrane. Depolarization is the process in which the potential difference of the cardiomyocytes changes rapidly to zero and causes the myocardial cells to contract. In a cardiac cycle of a healthy heart, the depolarization waves generated by the sinoatrial node cells propagate in the heart in an orderly manner, first to the entire atrium, and then to the ventricle through the "internal conduction pathway". If two electrodes are placed on any two sides of the heart, then the minute voltage changes between the two electrodes can be recorded during this process and can be displayed on the electrocardiogram or monitor. The electrocardiogram can reflect the rhythm of the whole heartbeat, as well as the weak part of the heart muscle.

Generally, more than two electrodes can be placed on the limbs, and they can be used as a pair for measurement (such as the left arm electrode (LA), the right arm electrode (RA), and the left leg electrode (LL) can be combined as follows: LA+RA, LA+LL, RA+LL). The output signal of each electrode pair is called a set of leads. Simply put, the lead is to look at the changes in the heart current from different angles. The types of ECG can be distinguished by leads, such as 3-lead ECG, 5-lead ECG and 12-lead ECG, etc. The 12-lead electrocardiogram is the most common type in clinical practice. It can record the potential changes of 12 sets of leads on the body surface at the same time, and depict the 12 sets of lead signals on the electrocardiogram. It is often used for one-time electrocardiogram diagnosis. 3-lead and 5-lead electrocardiograms are mostly used in situations where the electrical activity of the heart needs to be continuously monitored by a monitor, such as during surgery or during the monitoring of patients in an ambulance. Depending on the instrument, the results of this continuous monitoring may not be recorded completely.
The electrocardiogram is the best way to measure and diagnose abnormal heart rhythms. It is used to diagnose abnormal heart rhythms when the electrical conduction tissue of the heart is damaged, and changes in heart rhythm are caused by electrolyte imbalance. In the diagnosis of myocardial infarction (MI), it can specifically distinguish the area of myocardial infarction (but not all changes in the electrical activity of the heart can be recorded).
The electrocardiogram cannot fully evaluate the pumping ability of the heart, which is usually done by echocardiography or nuclear medicine. In some cases, patients with normal ECG images may have cardiac arrest (a condition called electrocardiomechanical separation).

The standard electrocardiogram is a twelve-lead (leads) system, that is, 12 leads ECG, which uses twelve leads located on the front and horizontal plane to record the electrical and physiological activities of the heart in twelve different directions. Observe the depolarization wave from two different angles, and then judge the location of myocardial damage based on the changes in the electrocardiogram. On the recording paper, these 12 signals are usually arranged in 4 columns and 3 rows.
The first column records the limb leads (Lead I, Lead II and Lead III). The second column records the compression unipolar limb leads (aVR, aVL, and aVF), and the last two columns record the chest leads (V1~V6). However, sometimes this arrangement is not used, so it is very important to check the label of each lead. The signals of the 3 leads in each column are usually recorded and printed out at the same time.
After a few cardiac cycles, go to the next column and start recording the next 3 leads. When recording different columns, the heart rhythm may change. The length of each lead record may be very short, usually only 1 to 3 cardiac cycles (depending on the speed of the heart rate), so it may be difficult to analyze the changes in the heart rhythm based on these images. Therefore, 1 to 2 "rhythm belts" are often printed in the electrocardiogram record. The rhythm zone usually chooses 2 leads (this lead can display the ventricular electrical signals and P waves most clearly), and the changes in the heart rhythm are displayed throughout the ECG recording (usually 5 to 6 seconds). The rhythm belt is also applied to the screen output during continuous ECG monitoring.