Are you still looking for a hydrogen peroxide sterilizer to sterilize surgical instruments?
If you have not purchased a plasma hydrogen peroxide sterilizer or plan to, congratulations. We have it on sale in September.

Item | Specifications |
Total volume | 130L |
Effective volume | 130L |
Product Size | 1660*860*1060(mm) |
Sterilizer size | 790*412*400(mm) |
Sterilizer structure and material |
Square cavity with stainless steel |
Operation method | LCD touch screen touch operation |
Sterilization method | 1. Hydrogen peroxide plasma technology, 2. No residual hydrogen peroxide, no environmental impact technology, working environment meets national standards. 3. Automatic detection of H2O2 injection system, which can automatically detect the volume of sterilized items and release unequal amounts of H2O2. |
Disinfectant | 1. 50% hydrogen peroxide solution; 2. The independent bottle type operation is more convenient, and the human body has no contact; 3. The amount of hydrogen peroxide in each mode is about 10ml |
Sterilization speed | 1 standard sterilization ≤35 minutes; 2. Surface sterilization can be shortened to 26 minutes. 3. Full load sterilization time ≤ 60 minutes. |
Sterilization mode | 1. Multi-program selection: standard sterilization, surface sterilization, preheat sterilization, advanced sterilization 2. Countdown display 3. Display of sterilization status in mode |
Sterilization temperature | 50 ℃ ± 5 ℃, the program will automatically terminate when sterilization is over temperature |
Sterilization effect | The sterilization program can effectively sterilize stainless steel tubes with a diameter of 1mm and a length of 500mm and PTFE tubes with a diameter of 1mm and a length of 2000mm. |
Main control system | 1. Imported embedded microcomputer control, with 7-inch original imported resistive touch screen LCD (color interface) operating system; 2. Parameters such as sterilization time are different for different modes; |
Sterilization records | 1. The pressure, time, cycle mode, process stage, etc. of the sterilization process are automatically displayed on the touch screen, and the working process is automatically printed. |
2. Automatic storage and retrieving system for printed information. The sterilizer can obtain sterilization information by inserting a USB storage device. The storage content: number, date, sterilization mode, and sterilization process information. The sterilization record can be stored not less than 5000 Times. Information such as pressure and temperature can be recorded and stored every second during sterilization. 3. The computer records all sterilization processes of the user, including the sterilization mode. | |
Alarm system | 1. Automatic alarm system, and touch screen text to display alarm content. With over-humidity fault alarm, hydrogen peroxide supply fault alarm, sterilization chamber temperature abnormal alarm, injection heater temperature abnormal alarm, sterilization door fault alarm |
2. Sterilization pressure and temperature with alarm settings. | |
3. Maintenance alarm prompts for key components such as vacuum pump oil change. | |
Sterilization room door | 1. LCD screen touch, automatic door opening and closing, photoelectric anti-pinch hand design; electric lifting door, equipped with a safety system on the door to ensure equipment and personal safety, anti-pinch hand design, foot sensor switch 2. The material of the cavity is stainless steel 304, the thickness is ≥8mm, and the material of the sealing door is high-quality aluminum, the thickness is ≥18mm. |
Vacuum pump | The vacuum pump has low noise, low emissions, fast evacuation, high stability, low maintenance costs, and an evacuation rate of 18 liters / second |
Sterilization residue | Non-toxic |
Vacuum pump oil replacement time | Use in a clean air environment, change every 180 days |
Impact on medical staff | The ultraviolet rays generated by the plasma are completely shielded from the operator and completely invisible to the naked eye. |
Fully equipped with supplies | Plasma special chemical instruction card, chemical instruction label, packaging bag, sterilant, self-contained biological indicator. |
Power Supply | AC220V,50Hz、3.6KW |
The key components | Vacuum pump, pressure transmitter, solenoid valve, air filter, embedded microcomputer, temperature controller, relay, etc. |
Work environment | Install and make use of it at indoor Ø Temperature: 5℃~40℃ Ø Humidity : 30%~80% Mains voltage fluctuation:110V±10% Altitude is at most 2000m Transient overvoltage category:Ⅱ Ø Rated pollution degree: 2 |